Universal uni-bipolar transmitter ใหม่จาก PR Electronics ต่อSCADAได้ PDF Print E-mail
Written by Administrator   
Tuesday, 02 July 2019 16:06

  • Measures DC inputs up to ±300 V / ±100 mA with spans as low as 25 mV / 0.5 mA
  • Passive/active current output and buffered voltage output
  • Fast < 20 ms response time and excellent 0.05% accuracy
  • Universally powered by 21.6…253 VAC / 19.2...300 VDC
  • เชื่อมต่อกับSCADAอย่างGENESIS32/GENESIS64เป็นต้นได้เพราะมีModbusโดยผ่านPR 4511 Modbus RTU enabler มีตารางModbus

 

 

 

Application
  • Fast < 20 ms response time for measuring signals produced by torque, position, current & acceleration sensors.
  • User configurable bipolar or unipolar I/O means the 4184 is suitable for nearly any DC voltage or current conversion.
  • Freely programmable between ±300 VDC and ±100 mA.
  • The excitation source allows measurement of a 2-wire or 3-wire transmitter, or a potentiometer.
  • Converts narrow bipolar inputs to wide bipolar or unipolar outputs, e.g., ±1 volt input = ±10 volt or 4...20 mA output.
  • Configurable input limits control the output value for increased safety.
  • ±20 VDC buffered voltage output for controlling devices like the PVG 32 valve (6...18 VDC).
  • The 4184 has been designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
Technical characteristics
  • The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
  • Possibility of output safety readback by selecting S4...20 mA output.
  • The current output can drive up to 1000 Ohms, with an adjustable response time of 0.0…60.0 seconds.
  • Exceptional mA output load stability of < 0.001% of span / 100 Ohm.
  • Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
  • Meets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.
  • Each unit is tested to a high 2.3 kVAC, 3-port galvanic isolation level.
  • Excellent signal to noise ratio of > 60 dB.
Mounting / installation / programming
  • Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
  • Configuration, monitoring, 2-point process calibration and more are accomplished using PR's 45xx detachable displays.
  • All programming can be password-protected.

 

 

Data sheet

 

Manuals

 
Modbus configuration manual

 

4801 Gateway manual

 

สอบถาม/ขอราคา

Last Updated ( Tuesday, 02 July 2019 08:39 )
 